Tripp Lite PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA, Switched, 2U, Single-phase, Horizontal, Metal, Black
PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA
The PDUMH32HVATNET 7.4kW Single-Phase 230V ATS/Switched PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 2U of space in EIA-standard racks and features 18 switched outlets (16 C13 and two C19) in two load banks, each bank protected by a 20A circuit breaker.
Dual 3-meter input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase 230V power sources. The PDU constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 15 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption.
Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet
or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Supports user-programmable startup of outlets in any order or interval to ensure network items are turned on in the proper sequence and reliably discovered. Digital LED display indicates power availability, voltage, source A/B input status, output load and power factor, as well as temperature and humidity with the optional temperature sensor (sold separately).
Primary and Secondary Inputs for Power Redundancy
Provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
Dual 3m input cords with IEC309 32A Blue (2P+E) plugs connect to separate primary and secondary single-phase power sources
Automatic Transfer Switching
Dynamic solid-state (TRIAC) automatic transfer switching
Switches to secondary power source if primary source fails or becomes unstable
15 ms transfer time ensures uninterrupted operation of connected equipment
Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source
Multifunction Digital LED Display
Reports source A and source B input power status and other information, including power availability, line voltage, frequency, amps, kilowatts and power factor
Advanced Network Monitoring
Built-in Ethernet network interface allows remote access for power monitoring, configuration, control and notification via web browser, SSH, telnet or SNMP
Real-time load/current data with billing-grade accuracy (+/- 1 percent)
Automated alerts help prevent accidental overloads, power loss and downtime
Optional temperature sensor (sold separately) monitors temperature and humidity
Broad Communications Compatibility
Supports HTTP, HTTPS, PowerAlert, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP
20A Circuit Breakers
Protect each of 2 single-phase output banks
Front-panel LED indicates when breaker has tripped
Cord Retention Brackets
Secures equipment power cords to reduce cable clutter and increase accessibility to connected components
Mounts Horizontally in 2U of Rack Space
Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
Single-phase IEC309 32A Blue (2P+E) input and 230V output
16 C13 and 2 C19 switched outlets in 2 load banks
Automatic transfer switching within 15 ms
Ethernet network interface for remote access
Digital LED display for real-time status monitoring
Package Includes
PDUMH32HVATNET 7.4kW Single-Phase 230V ATS/Switched PDU
Rack-mounting brackets
Cord retention brackets
Cable ties
Owners manual PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA
Further details for this product, PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA, can be found at the manufacturer website. Please note, these web addresse(s) are supplied by 3rd parties, Quzo UK is not responsible for the content.
7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA
Tripp Lite PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA. PDU types: Switched, Rack capacity: 2U, Type: Single-phase. AC outlets quantity: 18 AC outlet(s), AC outlet types: C13 coupler, C19 coupler, Power plug: IEC309. Cable length: 3 m. Supported network protocols: HTTP, HTTPS, PowerAlert®, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP. Nominal input voltage: 200-240 V, Maximum curr
Warranty information: 2-year limited
Initial Release Date: 31/08/2017
Read more »
Tripp Lite PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V IEC309 32A Blue Inputs, 16-C13 2-C19 Outlets, 2U, TAA PDUMH32HVATNET Specifications
Product Type
Power Distribution Unit
Product Type
Power - PDU
Collection Model Tripp Lite PDUMH32HVATNET 7.7kW Single-Phase Switched Automatic Transfer Switch PDU, Two 200-240V I
Manufacturer Product Type
Tripp Lite Power - PDU
Product colour
Black
PDU types Switched
LED indicators Yes
Housing material Metal
Display LCD
AC outlets quantity 18 AC outlet(s)
Ethernet LAN (RJ-45) ports 1
Power plug IEC309
AC outlet types C13 coupler, C19 coupler
Maximum current 32 A
AC input frequency 50 - 60 Hz
Maximum power 7700 W
Type
Single-phase
Height 88.9 mm
Width 444.5 mm
Depth 317.5 mm
Dimensions (WxDxH) 444 x 317 x 88 mm
Weight 6.21 kg
Mounting Horizontal
Supported network protocols HTTP, HTTPS, PowerAlert, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP
Year 2017
Rack capacity 2U
Country of origin Taiwan
Storage temperature (T-T) -15 - 50 C
Operating relative humidity (H-H) 5 - 95%
Products per master (outer) case 1 pc(s)
Sustainability certificates RoHS
Compliance certificates RoHS
Manual Yes
Package dimensions (WxDxH) 424 x 505 x 198 mm
Package width 457.2 mm
Package depth 497.8 mm
Package height 198.1 mm
Package weight 9.12 kg
Nominal input voltage 200-240 V
Nominal output voltage 200-240 V
Cable Length 3 m
MPN PDUMH32HVATNET