General Information for APC UPS
APC Smart-UPS On-Line, 1000VA/1000W, Tower, 230V, 6x C13 IEC outlets, SmartSlot, Extended runtime, W/O rail kit, Double-conversion (Online), 1 kVA, 1000 W, Sine, 220 V, 240 V
Smart-UPS On-Line, 1000VA/1000W, Tower, 230V, 6x C13 IEC outlets, SmartSlot, Extended runtime, W/O rail kit
High density, double-conversion on-line power protection with scalable runtime
Includes: CD with software, Comms cable, Documentation CD, Installation guide, Removable support feet, USB cable, Warranty card
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
ECO Mode
Operating mode that by-passes unused electrical components in good power conditions to achieve high operating efficiency without sacrificing protection
LCD graphics display
Text and mimic diagrams that display modes of operation, system parameters and alarms.
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Scalable runtime
Allows additional run time to be quickly added as needed.
Hot-swappable batteries
Ensures
clean, uninterrupted power to protected equipment while batteries are being replaced
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
LED status indicators
Quickly understand unit and power status with visual indicators.
Serial connectivity
Provides management of the UPS via a serial port.
InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.
SmartSlot
Customize UPS capabilities with management cards.
Network manageable
Provides remote power management of the UPS over the network.
Flash upgradeable firmware
Install maintenance releases of firmware remotely using FTP.
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Rack/Tower convertible
Protects the initial investment in the UPS when migrating from tower to rack-mount environment.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Audible alarms
Provides notification of changing utility power and UPS power conditions
Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
Cold-start capable
Provides temporary battery power when the utility power is out.
Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse. (Not available on Wall Tap SKUs) Smart-UPS On-Line, 1000VA/1000W, Tower, 230V, 6x C13 IEC outlets, SmartSlot, Extended runtime, W/O rail kit
Further details for this product, Smart-UPS On-Line, 1000VA/1000W, Tower, 230V, 6x C13 IEC outlets, SmartSlot, Extended runtime, W/O rail kit, can be found at the manufacturer website. Please note, these web addresse(s) are supplied by 3rd parties, Quzo UK is not responsible for the content.
Smart-UPS On-Line, 1000VA/1000W, Tower, 230V, 6x C13 IEC outlets, SmartSlot, Extended runtime, W/O rail kit
APC Smart-UPS On-Line, 1000VA/1000W, Tower, 230V, 6x C13 IEC outlets, SmartSlot, Extended runtime, W/O rail kit. UPS topology: Double-conversion (Online), Output power capacity: 1 kVA, Output power: 1000 W. AC outlet types: C13 coupler, Power plug: C14 coupler, AC outlets quantity: 12 AC outlet(s). Battery technology: Sealed Lead Acid (VRLA), Battery voltage: 48 V, Typical backup time at full load: 8 min. Form factor: Rackmount/Tower, Product colour: Black, Rack capacity: 2U. Width: 85 mm, Depth
Warranty information: 3 years repair or replace (excluding battery) and 2 years for battery
Initial Release Date: 28/08/2020
Read more »
APC Smart-UPS On-Line, 1000VA/1000W, Tower, 230V, 6x C13 IEC outlets, SmartSlot, Extended runtime, W/O rail kit, Double-conversion (Online), 1 kVA, 1000 W, Sine, 220 V, 240 V SRT1000XLI Specifications
Product Type
UPS
Brand
APC
Collection Model APC SRT1000XLI
Collection Model APC Smart-UPS On-Line, 1000VA/1000W, Tower, 230V, 6x C13 IEC outlets, SmartSlot, Extended runtime,
Manufacturer Product Type
APC UPS
Form Factor
Tower
Product colour
Black
Form Factor
Rackmount/Tower
Cooling type Active
LED indicators Status
LED indicators Yes
Display LCD
Product Family SRT1000XLI
Display type LCD
USB port Yes
Serial Interface Yes
AC outlet types C13 coupler
Power plug C14 coupler
AC outlets quantity 12 AC outlet(s)
Serial ports quantity 1
Serial interface type RJ-45
SmartSlot Yes
Battery voltage 48 V
Battery technology Sealed Lead Acid (VRLA)
Typical backup time at full load 8 min
Typical backup time at half load 21 min
Battery recharge time 3 h
Hot-swap battery Yes
Automatic battery test Yes
Cold start Yes
Battery weight 29.6 kg
Built-in fan Yes
Height 85 mm
Depth 505 mm
Width 432 mm
Height 432 mm
Battery width 59.4 cm
Weight 20.5 kg
Battery depth 74.9 cm
Battery height 24.6 cm
Width 85 mm
International Protection (IP) code IP20
Year 2020
ECO mode Yes
UPS topology Double-conversion (Online)
Output power capacity 1000 VA
Output power capacity 1 kVA
Output power 1000 W
Waveform Sine
Input operation voltage (min) 220 V
Input operation voltage (min) 50 V
Input operation voltage (max) 240 V
Input operation voltage (max) 150 V
Input frequency 40/70 Hz
Output operation voltage (min) 220 V
Output operation voltage (min) 50 V
Output operation voltage (max) 240 V
Output frequency 50/60 Hz
Surge energy rating 432 J
Crest factor 3:1
Emergency Power Off (EPO) Yes
Output voltage Total Harmonic Distortion (THD) 2%
Noise level 50 dB
Rack capacity 2U
Audible alarm modes Alarm when on battery, Battery replacement
Auto-restart Yes
Harmonized System (HS) code 85078000
Audible alarm(s) Yes
Operating relative humidity (H-H) 0 - 95%
Operating temperature (T-T) 0 - 40 C
Non-operating altitude 0 - 15240 m
Storage relative humidity (H-H) 0 - 95%
Storage temperature (T-T) -20 - 50 C
Operating altitude 0 - 3048 m
Certification CE, EAC
Quantity per pallet 12 pc(s)
Products per pallet 12 pc(s)
Sustainability certificates RoHS
Sustainability certificates CE
Sustainability certificates Green Premium
Sustainability certificates CE, Green Premium
Sustainability compliance Yes
Compliance certificates CE
Cables included USB cable
Package depth 749 mm
Package width 594 mm
Package height 246 mm
Package weight 29.6 kg
Quick installation guide Yes
Cable Length 1.83 m
Cable Length 1.8 m
Battery life (max) 5 year(s)
Nominal output voltage 230 V
Nominal input voltage 230 V
MPN SRT1000XLI
| Manufacturer PDF Manual |
APC Smart-UPS On-Line, 1000VA/1000W, Tower, 230V, 6x C13 IEC outlets, SmartSlot, Extended runtime, W/O rail kit, Double-conversion (Online), 1 kVA, 1000 W, Sine, 220 V, 240 V SRT1000XLI Reviews